SHD-60AF Manual
9
Torque and Procedure Chart
Pulsation Chamber Assembly
Torque Value: 31 FT. LBS.
Procedure: See Head Installation Procedure Section
Head Assembly
Torque Value: 31 FT. LBS.
Procedure: Assemble head on the cylinder with head bolts started only, not tight. Snug (6) head bolts to light torque.
Tighten (6) head bolts to 31 Ft-lbs. torque, doing the (2) long center bolts first and the (4) short bolts last. After five
hours of use re-torque bolts to 31 Ft-lbs.
Cylinder Assembly
T
orque V
alue: 20 FT
. LBS.
Procedure: After assembling cylinder over pistons and setting into place, tighten (6) cap screws finger tight. In a
criss-cross pattern, tighten bolts evenly so all bolts are hand snug. Again in a criss-cross pattern torque each bolt to
20 Ft-lbs., checking each bolt twice.
After five hours of use, re-torque bolts to 20 Ft-lbs.
Connecting Rod
Assembly
Torque Value: 18 FT. LBS.
Procedure: Assemble rod onto the crankshaft taking care to align the machined surfaces together and tighten cap
screws finger tight. Tighten bolts until hand tight and torque to 18 Ft-lbs. Check twice the torque reading before final
assembly of the cylinders.
Hydraulic System:
The hydraulic system consists of the pump, oil
reservoir, filters and hoses. Installed on the
compressor is a valve block assembly that
controls the flow to the hydraulic motor. To this
block, a 1/2” high-pressure hose must be
attached. This hose comes from the hydraulic
pumps pressure side. A 3/4” minimum low-
pressure return line is connected to the oil
cooler outlet and is routed to the oil reservoir.
American Eagle recommends a sufficient sized
reservoir be provided which includes the proper
suction and return filters. The cooler on the
compressor is designed and sized to cool the
air compressor efficiently. An auxillary oil cooler
is required when additional hydraulically
Return Line
Pressure
Line
operated equipment are added to the hydraulic
system. Pressure on the return line exceeding
200 PSI can and will cause damage to the filter,
cooler, and components of the compressor
hydraulic system.