Troubleshooting
If symptoms of poor performance develop, the following chart can be used as a guide to investigate
and correct the problem. When diagnosing faults in operations of the air compressor, always check
that the hydraulic power source is supplying the correct hydraulic flow and pressure that is listed in
the compressor specification section of this manual. Note: To Operate, the American Eagle SHD-
60AF Compressor needs 10 GPM and 1800 PSI System Pressure.
Problem
Compressor locks up at 110
psi and higher while under
load:
Note: When checking
hydraulic pump flow,
make sure the air tank is
closed and the
compressor is running.
Compressor will not
operate:
Possible Cause
Weak Hydraulic Motor.
Faulty Hydraulic Pump.
Oil Pressure is low.
Air receiver is full.
12 Volt power is not going to the line
side of the pressure switch.
Faulty Pressure Switch.
Hydraulic Lines not installed correctly.
Air Couplers or hoses are blocked.
Inline Check-Valve is leaking.
Faulty Solenoid V
alve.
Compressor is locked up.
Hydraulic motor malfunctioning.
Hydraulic pump malfunctioning.
Solution
If the Hydraulic pump is supplying the
recommended amount of fluid to the hydraulic
motor, replace the hydraulic motor.
If the pump pressure is below the
recommended GPM, replace the Hydraulic
pump if necessary.
If the oil pressure gauge is reading in the red
area, the oil pressure is low. See the Low Oil
Pressure entry in this troubleshooting section.
Drain and activate pressure switch.
If there is no power going to the line side of the
pressure switch, trace the wire back to the
power source.
If there is no power going to the solenoid valve,
replace the pressure switch.
Reinstall hydraulic lines.
Locate and remove restriction.
Disassemble, clean, and reinstall or replace.
If there is power going to the pressure switch,
press down on the solenoid valve bypass
button. If the compressor starts to operate,
replace the solenoid valve.
Remove the coupler and lovejoy between the
compressor pump and the hydraulic motor.
T
urn the compressor over by hand. If the
compressor turns over freely, the pump is ok.
This indicates there is a possible hydraulic
problem.
Inspect and repair.
Check flow and pressure settings.